Barcov HPLC BRQ-3000 is an hplc product that is suitable for various needs in the laboratory, because it can be configured according to needs. Get the most appropriate laboratory instrument product according to your needs.
Overview Barcov HPLC BRQ-3000
Stop going to third-party labs and build your own! Get real-time data at your convenience. High-performance liquid chromatography is the golden industry standard for QA/QC of raw material and products. It identifies and measures any API’s and active ingredients of food content in a single analysis.
Liquid chromatography is a vitally important technology utilized across a number of industries, including food safety, cannabis/hemp production, pharmaceutical development, CMC, manufacturing and QA/QC, environmental monitoring and various industrial and consumer product applications. Although these industries may vary greatly, the LC applications they utilize all demand precision, accuracy and flexibility to meet their unique analytical goals.
Whether your application requires the ruggedness and precision of highperformance liquid chromatography (HPLC), offers the right technology to meet your analytical goals. Our analytical solutions, including a full suite of chromatography data system (CDS) software packages, consumables and service offerings, come together to deliver a total liquid chromatography solution to increase your throughput, reduce costs and limit unnecessary complexity in analytical processes.
Barcov HPLC is the right choice for your various laboratory needs.
Our Product Barcov HPLC BRQ-3000
Including a full suite of chromatography data system (CDS) software packages, consumables and service offerings, come together to deliver a total liquid chromatography solution to increase your throughput, reduce costs and limit unn ecessary complexity in analytical processes.
The BARCOV BRQ-3000 series HPLC has been designed to increase your laboratory productivity and throughput, even in the face of challenging budget and staffing situations.
Configure HPLC instruments, GLP settings, manage user accounts and track results.
Our Configuration Barcov HPLC BRQ-3000
- Isocratic Manual Injection
- Quaternary Autosampler Injection
- Quaternary Manual Injection
Isocratic System
This isocratic system could deliver one type of mobile phase. By combining the best performance cost ratio, system stability and maintenance simplicity,this system is an ideal solution for routine QA/QC analysis and GPC/SEC application. It can also be simply upgraded into gradient system with autosampler to boost your productivity.
Quaternary System
Quaternary system possesses the advantage of great flexibility, and it can further be automatized by combing our autosampler. This combination could fulfil the complex requirements from pharmacy, environmental, food safety, petrochemical engineering, agricultural & farming fields. With the control from BARCOV Chromatography workstation, it realized full automatic analysis, report, system flush, shut down and then raised up the efficiency.
Modules of Barcov HPLC BRQ-3000
- AUTOSAMPLER BRQ-3320
- HPLC PUMPS BRQ-3320
- OVEN BRQ-3400
- UV-VIS DETECTOR BRQ-3500
AUTOSAMPLER BRQ-3320
Designed to significantly speed up analysis of routine sampling. The BRQ-3320 comes standard with 2 x 48 vial sample trays with ability to optionally expand up to 2 x 96 or 2 x 384 sample trays in addition to accommodating standard high or low plate or vial.
The Autosampler has a Multi Injection Mode capability supporting full loop, partial loop and micro pick up without changing any hardware. Critical to sample analysis is cleanliness and avoiding cross contamination, the design of the BARCOV BRQ-3320 Autosampler achieve this by employing a double wash system, one for cleaning the outer needle and pickup surfaces and a second, separate wash for the needle inner parts.
Maintenance is also key to achieving quality test results and ensuring the maximum lifespan out of the Autosampler. With the BRQ-3320, all maintenance parts are easily accessed via the front of the instrument, no complex disassembly required
HPLC PUMPS BRQ-3320
- High pressure up to 9000 psi (62 MPa) pump with flow rates up to 10 mL/min
- Pumps include overpressure and leakage alarms to improve safety and pump reliability
- Pump with precision feedback control design to increase pressure stability
- Quaternary system with an innovative gradient proportionate valve to achieve less than 1% gradient accuracy
At the heart of HPLC system is a high pressure pump used to transmit the mobile phase solvents, combined with the sample under test, into a chromatographic column. The BARCOC BRQ-3200 series pumps deliver the pressure needed to overcome the resistance of the column while providing stable pressure (non-pulsating) at precisely controlled flow rates.
The BARCOV BRQ-3200 pumps employ a combination of control algorithms and double plunger constant flow pump design to achieve precise flow and pressure control. The BARCOV double plunger pump design integrates a primary stage to transmit fluids and secondary stage working in tandem to control pulsation and flow rate. The BRQ-3200 series pumps include overpressure and leakage alarms to improve safety and pump reliability.
BRQ-3210 HPLC ISOCRATIC PUMP
One dual stage pump for isocratic elution
BRQ-3245 HPLC QUATERNARY PUMP
Quaternary electromagnetic distribution valve to control flow of 4 solvents of differing polarities under low pressure. One dual stage high pressure pump to transmit combined liquids to the chromatographic column. Combined the quaternary valve and high-pressure pump produce isocratic or gradient elution.
Isocratic versus Gradient Elution
- With Isocratic elution, the mobile phase is kept at a constant over the analysis period. Isocratic elution is best suited for samples that have few components and similar characteristics.
- In gradient elution mode, the mobile phase is composed of solvents having different polarities, controlling the proportions of which alters the capacity factor k (retention of an analyte on the chromatographic column) thus optimizing component separation in the shortest amount of time.
- Gradient elution improves degree of separation, reduces analysis time and increases sensitivity, therefore best applies to analysis of complex components or those that have considerable differences in polarity.
OVEN BRQ-3400
The BARCOV BRQ-3400 Column oven is designed to accurately control mobile phase temperatures using semiconductor heating and precision temperature control algorithm. Regulating the mobile phase temperatures reduces effect of any temperature variation has on the column and elution, producing more accurate results.
UV-VIS DETECTOR BRQ-3500
Ultraviolet and visible light detector with wide 190 nm to 800 nm wavelength range. High sampling speed to detect peaks of less than 5s. Dual light source provides wide linearity range with low noise. Easy to access flow cell makes maintenance simple. Ultraviolet and visual spectrum detector, a light source is passed through the sample contained in a flow cell, a photodiode and high-speed sampler measures the Flow cell output light intensity.
The BARCOV-3500 UV-Vis Detector based on Lambert-Beer Law where the concentration and light path length are constant, the absorbance of the sample can be calculated. The UV-Vis Detector includes two light sources, a Deuterium lamp with wavelength of 190 nm to 422 nm and a Tungsten lamp that extends the range from 422 nm to 800 nm. The BARCOV UV-Vis incorporates unique electrical and mechanical design to achieve low noise, high sensitivity and flow cell that is easy to maintain.
Specification HPLC
Solvent Organizer
Detail | BRQ-3110 | BRQ-3120 |
Online Wash | Standard Configuration | |
Online Degassing | None | 2-Channel (480µL/channel) |
Delivery Pump
Detail | BRQ-3210 Isocratic Pump | BRQ-3220 Binary Pump | BRQ-3245 Quarternary Pump |
Online Degassing | None | None | 4-channel (480µL/channel) |
Flow Rate Range | 0.001mL/min – 10.000mL/min (increment 0.001mL/min) | ||
Flow Rate Accuracy | ±0.5% (@1mL/min, water) | ||
Flow Rate Precision | ≤0.1%(mL/min, water)(JJG) | ||
≤0.07% RSD(@1mL/min, water)(ASTM) | |||
Max. Pressure | 9,000 psi (@0-2mL/min) | ||
6,000 psi (@2-5mL/min) | |||
3,000 psi (@5-10mL/min) | |||
Pressure Pulsation | ≤1%(@mL/min, water, backpressure > 10Mpa) | ||
Gradient Accuracy | None | ±0.5% | |
Gradient Reproducibility | ≤0.2% SD | ≤0.2% SD |
Autosampler
Detail | BRQ-3320 Autosampler | |
Sampling Mode | Full loop, partial loopfill and µl pick-up | |
Volume of Sample Loop | standard: 100 µL (optional for 10,20, 100µL) | |
Max. Sampling Volume | Full loop = loop volume | |
Partial loop fill = 1/2 loop volume | ||
µl pick-up = (loop volume- 3 x needle volume)/2 | ||
Sample Volume | 2*48 1.5mL vials(standard) | |
(Optional: 96-hole panel, 384-hole panel, 10mL bottle) | ||
Cross Contamination | < 0.02% | |
Linearity | 0.9999 | |
Pressure limit | 6000 psi (15,000 psi sampling valve is optional) |
Column Oven
Detail | BRQ-3400 Column Oven | |
Temperature Range | Room Temp +5°C – 70°C | |
Temperature Accuracy | ± 1.0 °C | |
Temperature Stability | ± 0.1 °C | |
Column Load | 250mm column x1, 50mm guard column x1 |
UV-Vis Detector
Detail | BRQ-3500 UV-VIS Detector |
Wavelength | 190-800 nm |
Light Source | Deuterium lamp, Tungsten lamp |
Spectral Width | 8nm |
Wavelength Accuracy | ±1 nm |
Wavelength Precision | 0.2 nm |
Noise | ±0.5×10-5 AU (JJG) |
±0.35×10-5 AU (ASTM) | |
Drift | 1×10-4 AU/Hr |
Linear Range | >5×104(JJG) |
>2.5AU (ASTM) | |
Max. Sampling | Rate 100 Hz |
Flowcell Pressure | 1200 PSI |
Flowcell Light Path | 10 mm |
Flowcell Volume | 12μL |
Detection Limit | 5×10-9 g/mL |
Application And Solution Barcov HPLC BRQ-3000
- Cation Analysis. Content determination of Sodium dan Potassium compounds by HPLC with Conductivity Detector.
- Anion Analysis. Content determination of Chlorine compounds by HPLC with Conductivity Detector.
- Pharmaceutical Analysis. Determine the content of soybean isoflavones in soybean isoflavone soft capsule by Barcov HPLC BRQ-3000 system with core-shell column
- Environment Protecion. Content determination of phenols compounds by HPLC.
- Food Safety. Simultaneously determining the content of 8 kinds of organic acids and vitamins in fruit by using HPLC.
- Agriculture. Simultaneous determining the content of 4 kinds of sulfa-drugs in fodder by using HPLC.
- Chemical. Simultaneously determining the content of 6 kinds of UV absorbers in cosmetics.
- Antibiotics. Determining the content of terramycin, doxycycline, tetracycline and auromycin by HPLC.
For more information and product discussion, you can contact PT. Barcov Teknologi Indonesia via whatsapp at number 0877-7727-7755. See also a demo of the Barcov HPLC BRQ-3000 tool unit directly at the following Google Maps.